A double hydraulic power unit is a power pack with two servo valves on one oil reservoir, so that one unit drives two independent web guides. Krishna Engineering Works builds double and triple power units, with two and three servo valves on the same reservoir, for machines with multiple guiding applications, in a model range from 0.25 HP to 3 HP.
What is a double hydraulic power unit?
A double hydraulic power unit is one tank, one housing and one position on the floor doing the work of two power packs. Each servo valve has its own sensor and its own cylinder, so each guide corrects its own web without reference to the other. A triple unit adds a third valve, sensor and cylinder in the same way.
What the guides share is the oil. They draw from the same reservoir, return to it, and depend on the same filtration and the same oil level. What they do not share is the control loop: each sensor steers only its own valve.
The idea follows from how a guiding power pack spends its time. A guide corrects in short, small movements, and between corrections its valve is closed and its oil flow is spare. One hydraulic supply can therefore look after more than one guide, provided the unit is sized for the moments when all of them move together.
How do two or three servo valves share one reservoir?
Each valve takes pressure oil from the supply side of the unit and returns it to the common tank. The circuit principle is the one used throughout fluid power: several consumers fed in parallel, each with its own control valve.
- The motor and pump side of the unit draws oil from the reservoir and holds the pressure line ready.
- Each servo valve is connected to that pressure line and to the return line.
- Each valve receives the signal of its own sensor only, by air pipe or by cable according to the sensing method.
- When one sensor reports an error, its valve opens and oil flows to its cylinder. The other valves stay closed.
- The oil displaced from the far side of that cylinder returns through the same valve to the tank.
- When two or three guides correct at once, the supply side must cover the sum of their demands.
How the supply side is arranged for a given duty, and how the valves are mounted, is settled when the unit is designed for the machine. The buyer’s part is to state every guide the unit must drive and the load on each.
When can one tank serve several guides?
One tank can serve several guides when the guides are close together, similar in duty and stopped together. The table sets out the conditions that favour a shared unit and those that favour separate packs.
| Condition on the machine | Shared double or triple unit | Separate single units |
| Guides within a short pipe run of one point | Suits well | Not needed |
| Guides at opposite ends of a long line | Long oil pipes slow the cylinders | Better choice |
| Guides that always run together | Suits well | Not needed |
| One guide must run while another is serviced | A fault in the tank stops all | Better choice |
| Floor space is tight at the unwinds | One unit to place | Two or three to place |
| Loads of very different size | Possible, but state both loads | Often simpler |
| Machine builder wants one hydraulic point per machine | Suits well | More wiring and piping |
The governing limit is pipe length. Oil lines add pressure loss and delay with every metre, so a shared unit belongs in the middle of the guides it feeds. If one guide would end up far from the tank, give that guide its own pack.
Which machines need two or three guides?
Any machine with more than one web, or more than one place where the edge matters, is a candidate. The examples below are typical layouts in converting plants.
- Lamination machines. Two webs meet at one nip, so each unwind needs its own guide. A double unit standing between the unwinds feeds both.
- Printing and coating lines. The web is guided at the unwind and again at the rewind, and on long lines once more before the process section.
- Slitter rewinders with a steering frame. The unwind is guided, and a tracking roller frame corrects the web again just before the knives.
- Lines with three unwinds. Triplex laminators and some coating lines bring three webs together, which is the natural duty of a triple unit.
- Twin lane machines. Two webs run side by side through one machine, each with its own edge to hold.
The page on the power pack for a lamination machine looks at the two web case in detail. Guiding positions in general are explained on the web guiding system page, and a mid machine guide acts on a tracking roller assembly.
Double hydraulic power unit or two single units?
Choose the double unit for compactness and simple upkeep, and two single units for independence. Neither is right for every machine, and the comparison below shows the trade.
| Point | One double unit | Two single units |
| Floor positions | One | Two |
| Oil to check, fill and change | One reservoir | Two reservoirs |
| Electrical supply points | One | Two |
| Pipe runs | Longer to at least one guide | Each pack beside its guide |
| Effect of a tank or supply fault | Both guides stop | One guide stops |
| Oil contamination | Reaches both valves | Stays in one circuit |
| Spares to hold | One set | One set if the packs are identical |
The shared oil is both the strength and the weakness of the design. One level to watch and one filter to change halves the routine work. On the other hand, dirt let into the tank during a careless top up reaches every valve on it, so clean filling matters even more than on a single pack.
How is a multi valve unit sized?
Size it guide by guide first, then add the guides together. Flow, pressure, tank volume and heat each need a separate look.
- Force for each guide. Work out the force each cylinder needs from the moving weight and the friction of its slides, exactly as for a single pack. The steps are set out on the hydraulic power pack page.
- Pressure. The line pressure must suit the guide that needs the most force. Lighter guides on the same unit simply work with pressure in hand.
- Speed for each guide. Each cylinder needs enough flow to follow its own web at full line speed.
- Simultaneous demand. Decide how many guides can correct at the same moment. At a reel change or a splice, all of them may.
- Tank volume. The reservoir must rest the oil of the whole unit, so that air and dirt separate out and heat is shed before the oil is used again.
- Motor rating. More flow at the same pressure needs more power. This is why the range runs from 0.25 HP for light duties up to 3 HP.
The published figures for the standard single models are a useful reference point when judging the size of each guide. A unit for several guides is then selected from the full data of the machine.
Installing a double or triple power unit
Install the unit centrally, pipe each guide as a separate circuit, and commission the guides one at a time. Most start up problems on multi valve units are crossed connections.
- Place the unit as near the middle of its guides as the layout allows, on a level base away from heat.
- Label each valve, each sensor and each cylinder with the same guide number before any pipe is connected.
- Run the oil pipes for each cylinder without kinks, and keep the circuits visibly apart.
- Run each sensor pipe or cable to its own valve, and check the labels again.
- Fill the tank with the oil grade named for the unit and check the motor rotation with a short start.
- Bleed one cylinder at a time by stroking it end to end.
- Commission the first guide fully, with its web threaded, before switching on the second.
- With all guides in automatic, disturb each web in turn and confirm that only its own cylinder responds.
- Top up the oil. Several pipes and cylinders take more oil from the tank than one does.
A crossed pair of sensors is easy to recognise: each stand moves when the other web is disturbed, and both run to the end of their stroke. Stop, swap the sensor connections and start again.
Faults particular to shared units
A fault that shows on every guide lies in the shared part of the unit, and a fault that shows on one guide lies in that guide’s own circuit. That rule shortens fault finding more than any other.
| Symptom | Where to look | First check |
| All guides slow | Shared supply side | Oil level, filter element, oil grade |
| All guides dead | Motor or supply | Rotation, electrical supply, oil level |
| One guide slow, others normal | That guide’s circuit | Its pipes, its cylinder, its valve |
| One guide slows when another corrects | Supply short of flow for both | Pipe restrictions, then the sizing data |
| Guides react to each other’s webs | Crossed sensor connections | Labels and connections |
| Oil runs hot | Tank level or ventilation | Level, air space around the tank |
| Guide furthest from the tank is lazy | Long oil pipes | Pipe length, bore and bends |
Filters, pipes, sensors and cylinder seals for these units are covered on the web aligner spare parts page. A unit with wear inside the pack can go to the repairs and servicing department.
Sensing on a multi valve unit
Each guide on the unit needs its own sensor, chosen for its own web. The hydro-pneumo web aligner senses with low pressure air, which suits clear films and dusty paper. The electro-hydro web aligner senses with a photocell and brings the controls to an electrical panel.
On a laminator the two webs are often different materials, for example a clear film and a foil or paper. State the material at each guide, so that the sensing at each position is proposed for the web it will actually read. The lamination machines themselves are shown on the main site’s lamination machine page.
What to send for a double or triple power unit quotation
Send the data for every guide on the unit, not only the heaviest. The list below covers what is needed.
- Machine type, and the number of guides to be run from one reservoir
- Position of each guide: unwind, mid machine or rewind
- Web material and width at each guide
- Heaviest reel or frame load at each guide, and how it is carried
- Line speed
- Distance from the proposed unit position to each cylinder
- Cylinder bore and stroke at each guide, if cylinders are already fitted
- Sensing method preferred at each guide: air sensor or photocell
- Electrical supply at the machine
Krishna Engineering Works invites enquiries from machinery manufacturers who buy power units in bulk. Send the details through the contact page, or see the whole range on the hydraulic power pack products page.
Frequently Asked Questions
What is a double hydraulic power unit?
A double hydraulic power unit is a hydraulic power pack with two servo valves mounted on one oil reservoir. Each valve has its own sensor and its own cylinder, so the unit drives two web guides that work independently. It takes one position on the floor and has one oil level and one filter to look after.
What is the difference between a double and a triple power unit?
The difference is the number of guides served. A double power unit carries two servo valves on the reservoir and drives two guides. A triple power unit carries three and drives three. In both, every guide has its own sensor and cylinder, and all of them draw oil from the same tank and return to it.
Do the guides on a double unit affect each other?
They should not in normal running. Each sensor steers only its own valve, so a correction on one web does not move the other. The guides share the oil supply, however, so a unit that is too small can slow one cylinder while another is moving. Correct sizing for simultaneous movement prevents this.
Can one power unit feed guides at both ends of a long machine?
It can, but it is rarely the right choice. Long oil pipes add pressure loss and delay, which makes the distant cylinder slow and less stable. A shared unit works best in the middle of guides that are close together. Where the unwind and rewind are far apart, separate packs beside each guide usually perform better.
What happens to the other guides if one develops a fault?
It depends on where the fault is. A fault in one guide’s own circuit, such as a damaged sensor or a leaking cylinder, affects only that guide. A fault in the shared part, such as a low oil level or a blocked filter, affects every guide on the unit. That is the main trade for the saving in space.
Which motor size does a double or triple unit need?
The motor size follows from the flow and pressure the guides need together, so it cannot be named without the machine data. KEW power pack units are available in different models from 0.25 HP to 3 HP. Send the load, speed and position of every guide, and the model is selected to cover them.
Can a single power pack be converted into a double unit later?
Treat that as a question for the maker, not as a site modification. Adding a valve changes the flow the unit must supply and the oil the tank must rest, so the original unit may be too small. If a second guide is likely in future, say so when ordering, so that the unit can be chosen with it in mind.